in  Show more search options Additional Search Options
 
  • 350 leading medical journals
  • 28 specialties covered
  • Ranked, rated and reviewed by experts
  • Delivered on your terms
Subscribe

Closure of Large Patent Ductus Arteriosus in Infants
Lin, C...-.C..., Hsieh, K...-.S..., Huang, T...-.C... | Am J Cardiol | vol. 103, 857 - 861, 2009

To view our Expert Rating and Evidence Rank Login or Subscribe Read the Article Rate this Article

SUBJECT Cardiology  >  Pediatric Cardiovascular Disease

Abstract

The purpose of this study was to evaluate the feasibility, clinical outcome, and resource utilization of transcatheter closure of large, symptomatic patent ductus arteriosus (PDA) in young infants, and compare the results with those of surgery. From January 2003 to December 2006, successful transcatheter implantation of the Amplatzer duct occluder was performed in 20 young infants (≤3 months of age) with large PDA who suffered from severe congestive heart failure despite medical treatment. The data was compared with a historical control of 18 young infants who underwent surgical ligation of PDA. Patient ages ranged from 18 to 89 days (mean 51.8) in the study group and 13 to 82 days (mean 39.9) in the control group. Patient weight ranged from 2.7 to 7.1kg (mean 4.24) in study group and 2.5 to 5.7kg (mean 3.79) in the control group. Between the 2 groups, there was no significant difference in the rate of complications. Patients who underwent transcatheter closure utilized significantly fewer resources (length of hospital stay and total cost) than those who underwent surgery. In conclusion, percutaneous device occlusion with Amplatzer duct occluder in small, symptomatic infants is feasible and more cost-effective compared with surgery. In experienced hands with careful preprocedural evaluation and delicate manipulation, the safety of transcatheter closure with Amplatzer ductus occluder in this age group can be assured and major complication avoided. Revision of the delivery sheath, making it kink-resistant, and PDA shape-tailored devices should further optimize the procedure.

Meet the Expert:
Thomas P. Graham, MD
Professor Emeritus of Pediatrics
Vanderbilt University School of Medicine
Division of Cardiology/ Vanderbilt Children’s Hospital Nashville, Tennessee

To view Expert Rating
Login or Subscribe

Home    Browse    Search    My Profile    My Alerts Top of page

Registered User Agreement  |  Contact Us  |  Privacy Policy  |  Terms and Conditions

Copyright © 2007, Elsevier Inc . All rights reserved.

Other web sites from Elsevier Health:
iConsult: Clinical Decision Support | ProceduresConsult | Expert Consult | Student Consult | Path Consult
USMLE Consult | The Clinics | OncologySTAT | The Lancet | ElsevierHealth.com | ElsevierHealthCareers.com
Imaging Consult

An Elsevier Product